Product Description
Company Profile
The company’s main products include desulfurization, dehydrocarbons, separation, compression, filling, storage and transportation equipment for natural gas extraction in oil and gas fields; complete sets of wellhead gas recovery equipment; complete sets of vented natural gas recovery equipment; complete sets of coalbed methane, shale gas and biogas development and utilization equipment Equipment; CNG filling station complete equipment; LNG complete equipment; BOG compressor; large-displacement screw-piston compound compressor; membrane nitrogen and adsorption nitrogen production complete equipment; in addition, hydrogen, oxygen, nitrogen, argon, carbon monoxide gas, carbon dioxide gas, coal gas, hydrogen sulfide gas, propylene gas, ethylene gas, methyl chloride gas, trifluoropropane gas, liquefied petroleum gas and other special gases, low-temperature gases and air compressors. Among them, the W and V series non-lubricated compressors produced by introducing advanced foreign technology have reached the international advanced level.
Product Description
The company currently has 10 series of leading products and hundreds of specifications. Its volumetric flow rate: 0.05~200m3/min. Pressure range: low pressure type 0~1.6MPa, medium pressure
Type 1.6~8.0MPa, high pressure type 8.0~50.0MPa. Lubrication methods are divided into 3 types: oil, oil-free and completely oil-free. The structural types include Z, W, V, D, M and H types. There are 3 cooling methods: air cooling, water cooling, and mixed cooling. In addition to providing users with customized products, we can also carry out personalized design and manufacturing according to user needs.
CNG STHangZhouRD STATION COMPRESSOR
CNG standard stations are built where natural gas pipelines pass through.
Gas is taken directly from the natural gas pipeline. Natural gas undergoes desulfurization, pressure regulation, metering, and
Filtration, dehydration and other processes enter the compressor unit, and then compress, cool and purify
Then the pressure is increased to 25Mpa, and finally the high-pressure trailer is supplied to the high-pressure trailer through the air filling column.
Fill up the gas, and also fill up the car through the gas vending machine. Our company can provide overall
Solutions and turnkey projects.
Equipment composition: air inlet filter pressure regulating metering device, desulfurization tower, low-pressure dehydration device, piston compressor, sequence control panel, gas storage bottle group, adding
Gas machines, gas filling columns, CNG trailers, gas alarm devices and other equipment.
Covered area: about 2000~4000m²
Optimal transportation radius: 150km
Suitable scale: ≥40000Nm²/d
Equipment installation time: about 30 days.
NO. | TYPE | Intake pressure MPa |
CAPACITY Nm3/h |
MOTOR KW |
COOLING | WEIGHT(TONS) | SIZE mm |
|||||
1 | W-5.6/0.5-250 | 0.05 | 500 | 160 | WATER COOLING | 9 | 5000×2300×2200 | |||||
2 | W-3.6/1-250 | 0.1 | 435 | 110 | WATER/MIX COOLING | 6 | 2400×2220×2150 | |||||
3 | W-4.75/1-250 | 0.1 | 570 | 132 | WATER/MIX COOLING | 6 | 2400×2220×2150 | |||||
4 | W-7.5/1-250 | 0.1 | 900 | 270 | WATER/MIX COOLING | 17 | 8500×2260×2200 | |||||
5 | W-4.5/1.4-250 | 0.14 | 650 | 160 | WATER/MIX COOLING | 7 | 3820×2270×2150 | |||||
6 | W-4.7/2-250 | 0.2 | 850 | 185 | WATER/MIX COOLING | 7 | 3820×2270×2150 | |||||
7 | WF-3.6/(1.5~2.5)-250 0.15~0.25 | 0.15~0.25 | 540~750 | 160 | AIR COOLING | 14 | 6200×2190×2080 | |||||
8 | W-3.6/(1.5~3)-250 | 0.15~0.3 | 540~860 | 185 | WATER/MIX COOLING | 7 | 4000×2270×2150 | |||||
9 | V-3.2/(3-5)-250 | 0.3~0.5 | 760-1150 | 220 | AIR COOLING | 14 | 6300×2525×2500 | |||||
10 | VF-3.2/(3~5)-250 | 0.3~0.5 | 770~1150 | 220 | WATER/MIX COOLING | 14 | 6300×2500×2500 | |||||
11 | W-1.5/8-250 | 0.8 | 810 | 132 | WATER/MIX COOLING | 8 | 4000×2300×2000 | |||||
12 | VF-2/(10~16)-250 | 1.0~1.6 | 1320~2000 | 280 | AIR COOLING | 10 | 5600×2500×2300 | |||||
13 | D-5/(2~4)-250 | 0.2~0.4 | 900~1500 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | |||||
14 | D-4.2/(3~6)-250 | 0.3~0.6 | 1000-1760 | 280 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | |||||
15 | D-3.6/(4~7)-250 | 0.4~0.7 | 1050~1730 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | |||||
16 | D-2.6/(7~12)-250 | 0.7~1.2 | 1250~2000 | 280 | WATER/AIR/MIX COOLING | 20 | 5000×3500×2500 | |||||
17 | VF-0.76/(7~13)-250 | 0.7~1.3 | 365~640 | 100 | WATER/AIR/MIX COOLING | 8 | 6000×2200×2230 |
CNG MOTHER STATION COMPRESSOR
The CNG mother station is built in a place where natural gas pipelines pass through.
Take the gas directly from the gas pipeline. Natural gas undergoes desulfurization, pressure regulation, metering, filtration,
Dehydration and other processes enter the compressor unit, and then are compressed, cooled and purified to make it
The pressure is increased to 25Mpa, and finally the high-pressure trailer is filled with air through the air filling column.
Sometimes, cars can also be refueled through gas vending machines. Our company provides turnkey projects.
Equipment composition: air inlet filter pressure regulating metering device, desulfurization tower, low pressure desulfurization tower
Water device, piston compressor, sequence control panel, gas storage bottle group, gas filling
machine, gas filling column, CNG trailer, gas alarm device and other equipment.
Covered area: about 2000~4000m²
Optimal transportation radius: 150km
Suitable scale: ≥40000Nm²/d
Equipment installation time: about 30 days.
NO. | TYPE | Intake pressure MPa |
CAPACITY Nm3/h |
MOTOR KW |
COOLING | WEIGHT(TONS) | SIZE mm |
||||
1 | D-5/(2-4)-250 | 0.2~0.4 | 900~1500 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
2 | VF-3.2/(3~5)-250 | 0.3~0.5 | 770~1150 | 220 | AIR COOLING | 14 | 6300×2500×2500 | ||||
3 | D-4.2/(3-6)-250 | 03~0.6 | 1000-1760 | 280 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
4 | D-3.6/(4~7)-250 | 0.4~0.7 | 1050~1730 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
5 | D-2.6/(7~12)-250 | 0.7~1.2 | 1250~2000 | 280 | WATER/MIX COOLING | 20 | 5000×3500×2500 | ||||
6 | VF-0.76/(7~13)-250 | 0.7~0.3 | 365~640 | 100 | MIX COOLING | 8 | 6000×2200×2230 | ||||
7 | D-2.8/(8-12)-250 | 0.8~1.2 | 1350-2150 | 280 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
8 | V-2/(9-14)-250 | 0.9~1.4 | 1200-1800 | 280 | WATER/AIR/MIX COOLING | 12 | 6500×2525×2300 | ||||
9 | VFD-2/14-210 | 1.4 | 1800 | 280 | AIR COOLING | 15 | 10000×4000×3000 | ||||
10 | D-2.5/(12-14)-250 | 1.2~1.4 | 1950-2250 | 18 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
11 | VF-2/(10~16)-250 | 1.0~1.6 | 1320~2000 | 280 | AIR COOLING | 10 | 5600×2500×2300 | ||||
12 | D-2.8/(10~16)-250 | 1.0~1.6 | 1800-2850 | 355 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
13 | V-1.43/(16~20)-250 | 1.6~2.0 | 1460~1800 | 220 | WATER/AIR/MIX COOLING | 11 | 6000×2500×2250 | ||||
14 | D-2.4/(16-20)-250 | 1.6~2.0 | 2450-3000 | 355 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
15 | D-2.4/(16-23)-210 | 1.6~2.3 | 2450-3450 | 355 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
16 | V-1.8/(18-23)-210 | 1.8~2.3 | 2000-2590 | 280 | WATER/AIR/MIX COOLING | 12 | 6500×2525×2200 | ||||
17 | D-1.45/(20-35)-250 | 2.0~3.5 | 1830-3100 | 280 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2500 | ||||
18 | V-0.8/(19~35)-250 | 1.9~3.5 | 960~1720 | 160 | WATER/AIR/MIX COOLING | 13 | 6500×2525×2200 | ||||
19 | VF-1/(25~40)-250 | 2.5~4.0 | 1560~2700 | 220 | AIR COOLING | 13.5 | 4250×2525×2100 | ||||
20 | D-1.45/(40~60)-250 | 4.0~6.0 | 3600~5300 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2100 | ||||
21 | D-1.3/(50-70)-250 | 5.0~7.0 | 3970~5530 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2100 | ||||
22 | D-1.3/(60-70)-250 | 6.0~7.0 | 4758~5530 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2100 | ||||
23 | D-1.2/(40-80)-250 | 4.0~8.0 | 4758~5530 | 315 | WATER/AIR/MIX COOLING | 23 | 5000×3500×2100 | ||||
24 | D-3.5/(7-10)-250 | 0.7~1 | 1680~2240 | 550 | AIR COOLING | 28 | 6600×4300×2500 |
CNG SUBSTATION COMPRESSOR
CNG substations are built in places where no natural gas pipelines pass through.
The CNG trailer transfers the gas from the mother station to the station and unloads the gas through the gas unloading column.
Gas machines refill cars.
Equipment composition: gas unloading column, sub-station compressor, sequence control panel, storage
Gas cylinder sets, gas dispensers, gas alarm devices, CNG trailers and other equipment.
Covered area: about 1000~1500m²
Way of working:
After natural balance, the direct intake air is compressed and supercharged, and the average working capacity is
More than 1000 square meters
Compressor exhaust volume changes range as trailer pressure drops:
1800-400Nm²/h
NO. | TYPE | Intake pressure MPa |
CAPACITY Nm3/h |
MOTOR KW |
COOLING | WEIGHT(TONS) | SIZE mm |
||||
1 | VF-0.32/(30~200)-250 | 3~20 | 1500 | 75 | AIR | 5.5 | 5538×2134×1680 | ||||
2 | VFD-0.32/(30~200)-250 | 3~20 | 1500 | 75 | AIR | 9.65 | 5538×2438×2438 | ||||
3 | DFD-0.32/(30-200)-250 | 3~20 | 1500 | 75 | AIR | 8.5 | 4400×2610×2591 | ||||
4 | VFD-0.32/(20~200)-250 | 2~20 | 1500 | 75 | AIR | 9.65 | 5538×2438×2438 | ||||
5 | VF-0.26/(30-200)-250 | 3~20 | 1000 | 55 | AIR | 5.5 | 5538×2350×2000 | ||||
6 | VFD-0.26/(30-200)-250 | 3~20 | 1000 | 55 | AIR | 9.5 | 5538×2350×2438 | ||||
7 | ZFD-0.1/(30~200)-250 | 3~20 | 650 | 37 | AIR | 8.5 | 7000×2700×2700 | ||||
8 | ZFD-0.24/(30-200)-250 | 3~20 | 1400 | 37×2 | AIR | 8.5 | 7000×2700×2700 | ||||
9 | KR-1500/(20-200)-250 | 2~20 | 1500 | 30×2 | AIR | 10 | 5500×2500×2950 | ||||
10 | KR-2000/(20-200)-250 | 2~20 | 2000 | 37×2 | AIR | 10 | 5500×2500×2950 | ||||
11 | DFD-3[0.28]/(2-4)[25-200]-250 | 0.2~0.4
2.5~20 |
540-900 (STANARD STATION AND SUBSTATION) 1300 |
160
75 |
AIR | 12.5 | 4050×3450×2100 |
Detailed Photos
After Sales Service
In addition to the high-quality performance of our products, we also attach great importance to providing customers with comprehensive services. We have an independent service operation and maintenance team, providing customers with various support and services, including technical support, debugging services, spare parts supply, renovation and upgrading, and major maintenance. We always adhere to the principle of customer-centrism, ensuring the safe and stable operation of customer equipment. Our service team is committed to providing reliable support for customers’ operations 24/7.
Training plan
Technical training is divided into 2 parts: company training and on-site training.
1)Company training
Before the unit is delivered, that is during the unit assembly period, users will be provided with a one-week on-site training by the company. Provide local accommodation and transportation facilities, and provide free venues, teaching materials, equipment, tools, etc. required for training. The company training content is as follows:
The working principle, structure and technical performance of the unit.
Unit assembly and adjustment, unit testing.
Operation of the unit, remote/local operation, manual/automatic operation, daily operation and management, familiar with the structure of each system of the unit.
Routine maintenance and upkeep of the unit, and precautions for operation and maintenance.
Analysis and troubleshooting of common faults, and emergency handling methods.
2) On-site training
During the installation and trial operation of the unit, on-site training will be conducted to teach the principles, structure, operation, maintenance, troubleshooting of common faults and other knowledge of the unit, so as to further become familiar with the various systems of the unit, so that the purchaser can independently and correctly operate the unit. Operation, maintenance and management.
Packaging & Shipping
/* March 10, 2571 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
After-sales Service: | 12 Month |
---|---|
Warranty: | 12 Month |
Lubrication Style: | Lubricated |
.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: |
|
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
What Is the Typical Lifespan of a Gas Air Compressor?
The typical lifespan of a gas air compressor can vary depending on several factors, including the quality of the compressor, its usage patterns, maintenance practices, and environmental conditions. However, with proper care and maintenance, a gas air compressor can last for many years. Here’s a detailed explanation of the factors that can affect the lifespan of a gas air compressor:
1. Quality of the Compressor:
The quality and construction of the gas air compressor play a significant role in determining its lifespan. Compressors made with high-quality materials, precision engineering, and robust components are generally more durable and can withstand heavy usage over an extended period.
2. Usage Patterns:
The usage patterns of the gas air compressor can impact its lifespan. If the compressor is used consistently and for extended periods, it may experience more wear and tear compared to compressors used intermittently or for lighter tasks. Heavy-duty applications, such as continuous operation with high-demand tools, can put more strain on the compressor and potentially reduce its lifespan.
3. Maintenance Practices:
Regular maintenance is crucial for extending the lifespan of a gas air compressor. Following the manufacturer’s recommended maintenance schedule, performing routine tasks like oil changes, filter cleaning/replacement, and inspection of components can help prevent issues and ensure optimal performance. Neglecting maintenance can lead to accelerated wear and potential breakdowns.
4. Environmental Conditions:
The operating environment can significantly impact the lifespan of a gas air compressor. Factors such as temperature extremes, humidity levels, presence of dust or debris, and exposure to corrosive substances can affect the compressor’s components and overall performance. Compressors used in harsh environments may require additional protection or specialized maintenance to mitigate these adverse conditions.
5. Proper Installation and Operation:
Proper installation and correct operation of the gas air compressor are essential for its longevity. Following the manufacturer’s guidelines for installation, ensuring proper ventilation, maintaining correct oil levels, and operating within the compressor’s specified capacity and pressure limits can help prevent excessive strain and premature wear.
Considering these factors, a well-maintained gas air compressor can typically last anywhere from 10 to 15 years or even longer. However, it’s important to note that this is a general estimate, and individual results may vary. Some compressors may experience shorter lifespans due to heavy usage, inadequate maintenance, or other factors, while others may last well beyond the expected lifespan with proper care and favorable conditions.
Ultimately, investing in a high-quality gas air compressor, adhering to recommended maintenance practices, and using it within its intended capabilities can help maximize its lifespan and ensure reliable performance for an extended period.
How Do You Transport Gas Air Compressors to Different Job Sites?
Transporting gas air compressors to different job sites requires careful planning and consideration of various factors. Here’s a detailed explanation:
1. Equipment Size and Weight:
The size and weight of the gas air compressor are crucial factors to consider when planning transportation. Gas air compressors come in different sizes and configurations, ranging from portable units to larger, skid-mounted or trailer-mounted compressors. Assess the dimensions and weight of the compressor to determine the appropriate transportation method.
2. Transportation Modes:
Gas air compressors can be transported using different modes of transportation, depending on their size, weight, and distance to the job site:
- Truck or Trailer: Smaller gas air compressors can be loaded onto a truck bed or trailer for transportation. Ensure that the vehicle or trailer has the necessary capacity to accommodate the weight and dimensions of the compressor.
- Flatbed or Lowboy Trailer: Larger gas compressors or skid-mounted units may require transportation on a flatbed or lowboy trailer. These trailers are designed to carry heavy equipment and provide stability during transportation.
- Shipping Container: For long-distance transportation or international shipments, gas air compressors can be transported in shipping containers. The compressor must be properly secured and protected within the container to prevent any damage during transit.
3. Securing and Protection:
It is essential to secure the gas air compressor properly during transportation to prevent shifting or damage. Use appropriate tie-down straps, chains, or fasteners to secure the compressor to the transport vehicle or trailer. Protect the compressor from potential impacts, vibrations, and weather conditions by using suitable covers, padding, or weatherproof enclosures.
4. Permits and Regulations:
Depending on the size and weight of the gas air compressor, special permits or escorts may be required for transportation. Familiarize yourself with local, state, and federal regulations regarding oversize or overweight loads, and obtain the necessary permits to ensure compliance with transportation laws.
5. Route Planning:
Plan the transportation route carefully, considering factors such as road conditions, height and weight restrictions, bridges, tunnels, and any other potential obstacles. Identify alternative routes if needed, and communicate with transportation authorities or agencies to ensure a smooth and safe journey.
6. Equipment Inspection and Maintenance:
Prior to transportation, conduct a thorough inspection of the gas air compressor to ensure it is in proper working condition. Check for any leaks, damage, or loose components. Perform routine maintenance tasks, such as oil changes, filter replacements, and belt inspections, to minimize the risk of equipment failure during transportation.
In summary, transporting gas air compressors to different job sites requires considering factors such as equipment size and weight, choosing appropriate transportation modes, securing and protecting the compressor, obtaining necessary permits, planning the route, and conducting equipment inspection and maintenance. Careful planning and adherence to transportation regulations contribute to the safe and efficient transportation of gas air compressors.
How Does a Gas Air Compressor Work?
A gas air compressor works by utilizing a gas engine to power a compressor pump, which draws in air and compresses it to a higher pressure. The compressed air can then be used for various applications. Here’s a detailed explanation of how a gas air compressor operates:
1. Gas Engine:
A gas air compressor is equipped with a gas engine as its power source. The gas engine is typically fueled by gasoline, diesel, natural gas, or propane. When the engine is started, the fuel is combusted within the engine’s cylinders, generating mechanical energy in the form of rotational motion.
2. Compressor Pump:
The gas engine drives the compressor pump through a mechanical linkage, such as a belt or direct coupling. The compressor pump is responsible for drawing in atmospheric air and compressing it to a higher pressure. There are different types of compressor pumps used in gas air compressors, including reciprocating, rotary screw, or centrifugal, each with its own operating principles.
3. Intake Stroke:
In a reciprocating compressor pump, the intake stroke begins when the piston moves downward within the cylinder. This creates a vacuum, causing the inlet valve to open and atmospheric air to be drawn into the cylinder. In rotary screw or centrifugal compressors, air is continuously drawn in through the intake port as the compressor operates.
4. Compression Stroke:
During the compression stroke in a reciprocating compressor, the piston moves upward, reducing the volume within the cylinder. This compression action causes the air to be compressed and its pressure to increase. In rotary screw compressors, two interlocking screws rotate, trapping and compressing the air between them. In centrifugal compressors, air is accelerated and compressed by high-speed rotating impellers.
5. Discharge Stroke:
Once the air is compressed, the discharge stroke begins in reciprocating compressors. The piston moves upward, further reducing the volume and forcing the compressed air out of the cylinder through the discharge valve. In rotary screw compressors, the compressed air is discharged through an outlet port as the interlocking screws continue to rotate. In centrifugal compressors, the high-pressure air is discharged from the impeller into the surrounding volute casing.
6. Pressure Regulation:
Gas air compressors often include pressure regulation mechanisms to control the output pressure of the compressed air. This can be achieved through pressure switches, regulators, or control systems that adjust the compressor’s operation based on the desired pressure setting. These mechanisms help maintain a consistent and controlled supply of compressed air for the specific application requirements.
7. Storage and Application:
The compressed air produced by the gas air compressor is typically stored in a receiver tank or used directly for applications. The receiver tank helps stabilize the pressure and provides a reservoir of compressed air for immediate use. From the receiver tank, the compressed air can be distributed through pipelines to pneumatic tools, machinery, or other devices that require the compressed air for operation.
Overall, a gas air compressor operates by using a gas engine to power a compressor pump, which draws in air and compresses it to a higher pressure. The compressed air is then regulated and used for various applications, providing a reliable source of power for pneumatic tools, machinery, and other equipment.
editor by CX 2024-01-08