{"id":1233,"date":"2024-05-13T04:31:42","date_gmt":"2024-05-13T04:31:42","guid":{"rendered":"https:\/\/gaspowered-aircompressor.com\/china-supplier-oxygen-concentrator-air-compressor-with-on-site-technical-service-with-great-quality\/"},"modified":"2024-05-13T04:31:42","modified_gmt":"2024-05-13T04:31:42","slug":"china-supplier-oxygen-concentrator-air-compressor-with-on-site-technical-service-with-great-quality","status":"publish","type":"post","link":"https:\/\/gaspowered-aircompressor.com\/hi\/china-supplier-oxygen-concentrator-air-compressor-with-on-site-technical-service-with-great-quality\/","title":{"rendered":"China supplier Oxygen Concentrator Air Compressor with on-Site Technical Service with Great quality"},"content":{"rendered":"
\n
\n

Product Description<\/h2>\n

\n

Oxygen Concentrator Air Compressor with On-site Technical Service\u00a0\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0<\/b> <\/p>\n

\u00a0\u00a0<\/b> <\/p>\n

\n

Introduction<\/p>\n

Our Oxygen Concentrator Air Compressor<\/b> is total oil free, do not use any lubricate oil, and for the cylinder use\u00a0stainless steel\u00a0material, piston ring is self-lubricated material, all this guarantee oxygen is clean and no-pollution.<\/p>\n

Oxygen Concentrator Air Compressor<\/b> working speed is slow, normally 200-400 rpm, to keep working do\u00a024 hours\u00a0heavy duty loading, this Oxygen Concentrator Air Compressor<\/b> main use for hospital oxygen supplier center, to increase oxygen supply line pressure to the room, also can boost oxygen, and filling to the cylinder, such as 15Mpa, 20Mpa. Our Oxygen Concentrator Air Compressor<\/b> can also be used in\u00a0Industrial acetylene cutting, cutting steel scrap in steel factory, support Boiler oxygen combustion recycle the cryogenic liquid oxygen tank vapor oxygen to the tank.<\/p>\n

Normally, according to customer oxygen application condition, our Oxygen Concentrator Air Compressor<\/b> has\u00a0one pressure stage, 2 pressure stage, 3 pressure stage, and 4 pressure stage, and 5 pressure stage, by the cylinder, has single, double, three, and 4 cylinder.<\/p>\n

\u00a0<\/p>\n<\/p>\n

\n

\n

\n

\n

\u00a0<\/p>\n

Main Technical Parameters<\/p>\n

\u00a0<\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
No.<\/b><\/td>\nItem<\/b><\/td>\nData<\/b><\/td>\n<\/tr>\n
1<\/td>\nCompressor model<\/td>\nGOW-40\/4-150<\/td>\n<\/tr>\n
2<\/td>\nCompressor type<\/td>\nV type, reciprocating piston, water cooled, air cooled<\/td>\n<\/tr>\n
3<\/td>\nCompression medium<\/td>\noxygen<\/td>\n<\/tr>\n
4<\/td>\nVolume flow<\/td>\n40nm3\/h<\/td>\n<\/tr>\n
5<\/td>\nIntake pressure<\/td>\n4bar<\/td>\n<\/tr>\n
6<\/td>\nExhaust pressure<\/td>\n150bar<\/td>\n<\/tr>\n
7<\/td>\nInlet temperature<\/td>\n\u226440\u00baC<\/td>\n<\/tr>\n
8<\/td>\nExhaust temperature<\/td>\nno more than ambient temperature +15\u00baC after cooling<\/td>\n<\/tr>\n
9<\/td>\nDriving mode<\/td>\nexplosion-proof motor<\/td>\n<\/tr>\n
10<\/td>\nExternal size (length \u00d7 width \u00d7 height)<\/td>\n1650*950*1470mm<\/td>\n<\/tr>\n
11<\/td>\nWeight<\/td>\n960kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

<\/p>\n

Precautions for Use<\/p>\n

1. Oxygen Concentrator Air Compressor<\/b> should be selected in a clean and dust-free room to work, the use of temperature should not be less than 0 \u00baC.
2. Oxygen Concentrator Air Compressor<\/b> can be bolted to a horizontal base or placed on a horizontal base table. A thick rubber plate with damping between the filling pump and the abutment shall be in contact with the base station smoothly.
3. Do not contact any fat object in contact with water, glycerin lubrication liquid.
4. Before the first use, the mechanical oil should be injected into the body, and after each replacement of mechanical oil, the body must be outside the grease wipe clean. Do not allow the oil from the upper and lower body joints, the sealing ring and the sealing cover outside the leakage.
5. Smoking is prohibited in the place of use, and strict forbidden prohibition system should be established. The filling workers must wear clean clothes without oil, and must wash their hands with soap before working.
6. Oxygen Concentrator Air Compressor<\/b> should be selected in a clean and non-greasy room to work, the use of environmental encounters not less than 0\u00baC, indoor lighting lines and power lines can not use the wire, the line connector must use explosion-proof junction box, oxygen filling indoor storage of large oxygen cylinders must not exceed the maintenance of good ventilation. The Oxygen Compressor and the large oxygen cylinder should be used in isolation.
7. Oxygen Concentrator Air Compressor\u00a0<\/b>to be horizontally placed on the ground, 4 legs cushion flat. Use the external air source tube to connect the gas source bottle with the Oxygen Compressor connecting pipe and the sealing ring of the body connection should be installed correctly.<\/p>\n

Why Choose Us<\/p>\n

*We will answer calls and receive consultation documents from customer politely and earnestly, to know exactly about customers’ site situation and technical requirements, and record all data in detail.
*We will carefully analyze the information supplied by customers, to provide catalog and technical proposal in time.
*We will contact customers regularly, actually knowing about the progress, thus can provide reasonable suggestions, to help customers reducing costs.
*We sincerely invite customers to visit our company, participating in technical discussion, to determine the best solution.
*If any trouble occurred during the equipment running period, our technicians will communicate with customers and help solve the problem in time.
*We will send technicians to help customers install, debug the equipment and train workers, until the workers are familiar with the operation, technical principle and simple maintenance of the system.
*All the equipment has 18-month warranty from delivery date.
*During the equipment running period, we will contact customers and ask for feedback regularly.<\/p>\n

\u00a0 \t\/* January 22, 2571 19:08:37 *\/!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(\/(.*?):(.*)$\/))&&1\t <\/p>\n

\n

\n