Product Description
2 ton Split Type Famous Japanese Compressor Hybrid solar conditioning
Product Details
When the power on, the compressor start working, it compress the refrigerant from low pressure to high pressure, low temperature to high temperature, then discharge to heat ex-changer of the solar collector,
In sunshine time ,the vacuum tube can absorb the sunshine to heat the water of the water tank, then the hot water will translate the heating to refrigerant by the ex-changer, then help the compressor heat the temperature and increase the pressure of the refrigerant again,so it just need use the small compressor driver the system running, just use the less power to cool or heat the room,to save more energy.
Hybrid solar air-conditioner is driven by electricity and with solar energy as an auxiliary power.The 2 kinds of energy work complementally in accordance with principles of fluid dynamics. It combines the absorption working system with compression system by using environmental-friendly media in cooling and heating on the basis of traditional air-conditioner technology to achieve energy-saving and environment protection.
Product Introduction
(9000BTU-24000BTU) for Wall Mounted range. Up to 48000btu for Cassette,Ducted, Floor standing,Floor ceiling series.
- on Grid Working with 50% solar energy
- Supreme high efficiency rating reach to 4.0
3.Fashion and Elegant Design, LED Display,Quiet Running
4.Vacuum thermal tube solar collector ,with easy installation and affordable cost
5. CZPT Compressor
6. Blue Coating Heat Ex-changer (Better heat transfer effect)
7.100% Copper Connection Pipes With Insulation
8.Environmental Friendly Gas R410A
Product Parameters
Freon:R410 | ||||||
Power Supply:220-240VAC, 1PH, 50/60Hz | ||||||
Performance | ||||||
Capacity | Cooling | Btu/h | 9000BTU | 11500BTU | 12000BTU | 18000BTU |
W | 2600 | 3200 | 3500 | 5200 | ||
Heating | Btu/h | 10000 | 12000 | 13000 | 20000 | |
W | 2900 | 3500 | 3800 | 6000 | ||
Noise | Indoor | dB(A) | ≤40 | ≤42 | ≤42 | ≤44 |
Outdoor | dB(A) | ≤50 | ≤52 | ≤52 | ≤54 | |
Air Circulation | m³/h | 500 | 520 | 550 | 800 | |
Suitable Area | m² | 11~17 | 13~21 | 15~23 | 26~36 | |
EER | W/W | 3.84 | 3.72 | 3.89 | 3.83 | |
Btu/h/w | 12.42 | 12.69 | 13.27 | 13.07 | ||
Power Consumption | ||||||
Power Input | Cooling | W | 650~770 | 780~940 | 800~1571 | 1100~1300 |
Heating | W | 650~780 | 780~950 | 800~1050 | 1150~1350 | |
Rated Current | Cooling | A | 3.00~3.60 | 3.55~4.27 | 3.70~4.80 | 6.30~7.30 |
Heating | A | 3.00~3.65 | 3.55~4.31 | 3.70~4.90 | 6.30~7.50 | |
Vacuum Tube | Diameter*Length*Pcs | 47*520*10 | 47*520*10 | 47*520*10 | 47*620*11 | |
Flat plate solar collector | WXDXH | 1000x550x90 | 1000x550x90 | 1000x550x90 | 1000x550x90 | |
Dimensions | ||||||
Indoor Unit | Net | mm | 775*265*210 | 775×265×210 | 775×265×210 | 985×300×220 |
Shipping | mm | 840*325*265 | 840×325×265 | 840×325×265 | 1080×380×300 | |
Outdoor Unit | Net | mm | 790*260*540 | 790*260*540 | 790*260*540 | 850*300*755 |
Shipping | mm | 910*370*610 | 910*370*610 | 910*370*610 | 950*410*760 | |
Water Tank | Shipping | mm | 910*400*330 | 910*400*330 | 910*400*330 | 980*400*370 |
Vacuum Tube | Shipping | mm | ||||
Flat plate solar collector | Shipping | mm | 1100x650x110 | 1100x650x110 | 1100x650x110 | 1100x650x110 |
Weight | ||||||
Indoor Unit | Net/Gross | kg | 9/10.5 | 10/11.5 | 10/11.5 | 16/17.5 |
Outdoor Unit | Net/Gross | kg | 31/34 | 36/38 | 38/40 | 50/52 |
Solar Collector | Net/Gross | kg | 13/15 | 13/15 | 13/15 | 16/17 |
Loading Qty | in 20feet | sets | 75 | 75 | 75 | 55 |
40HQ | sets | 175 | 175 | 175 | 125 |
Freon:R410 | |||||
Power Supply:220-240VAC, 1PH, 50/60Hz | |||||
Performance | |||||
Capacity | Cooling | Btu/h | 20000BTU | 24000BTU | 36000BTU |
W | 6000 | 7200 | 10000 | ||
Heating | Btu/h | 22000 | 27000 | 40000 | |
W | 6600 | 7900 | 11000 | ||
Noise | Indoor | dB(A) | ≤46 | ≤50 | ≤52 |
Outdoor | dB(A) | ≤56 | ≤58 | ≤60 | |
Air Circulation | m³/h | 850 | 1150 | 1350 | |
Suitable Area | m² | 25~42 | 30~48 | 40~60 | |
EER | W/W | 3.88 | 3.82 | 3.82 | |
Btu/h/w | 13.24 | 13.03 | 13.03 | ||
Power Consumption | |||||
Power Input | Cooling | W | 1350~1560 | 1700~1900 | 2400~2640 |
Heating | W | 1350~1590 | 1700~1950 | 2470~2650 | |
Rated Current | Cooling | A | 6.30~7.30 | 8.00~8.90 | 10.91~11.95 |
Heating | A | 6.30~7.50 | 8.00~8.90 | 11.23~12.05 | |
Vacuum Tube | Diameter*Length*Pcs | 47*620*11 | 47*620*11 | 47*620*11 | |
Flat plate solar collector | WXDXH | 1000x550x90 | 1000x550x90 | 900x500x80 | |
Dimensions | |||||
Indoor Unit | Net | mm | 985×300×220 | 985×300×220 | 1080×320×240 |
Shipping | mm | 1080×380×300 | 1080×380×300 | 1150×420×320 | |
Outdoor Unit | Net | mm | 850*300*755 | 850*300*755 | 865*310*710 |
Shipping | mm | 950*410*760 | 950*410*760 | 1571*395*790 | |
Water Tank | Shipping | mm | 980*400*370 | 980*400*370 | 980*400*370 |
Vacuum Tube | Shipping | mm | |||
Flat plate solar collector | Shipping | mm | 1100x650x110 | 1100x650x110 | 950x550x90mm |
Weight | |||||
Indoor Unit | Net/Gross | kg | 16/17.5 | 20/22 | 23/25 |
Outdoor Unit | Net/Gross | kg | 50/52 | 55/58 | 65/70 |
Solar Collector | Net/Gross | kg | 16/17 | 16/17 | 16/17 |
Loading Qty | in 20feet | sets | 55 | 55 | 50 |
40HQ | sets | 125 | 125 | 115 |
Product Details Show:
Solar air conditioner projects:
Product Processing
Product Packing
Hot Products
Why Choose Us?
1.Reply your inquiry in 24Hrs
2.Feedback of complaint in 24Hrs
3.OEM/ODM are accepted
4.Exclusive agents in local country are welcomed
5.Providing professional technical advice
6. Supergreen Tech Co.,Ltd, is a professional manufacturer of solar products such as Solar lights, Solar air conditioner, Solar refrigerators, Solar pest control lamp and so on.
With CE certification and several patent technology, making sure that we can provide all of our clients the best user friendly products!
FAQ:
Q1. Can I have a sample order for Solar air conditioner?
Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?
Sample needs 7-20 days, mass production time needs 3-6 weeks.
Q3. Do you have any MOQ limit for air conditioner order?
Low MOQ, 1pc for sample checking is available
Q4. How do you ship the goods and how long does it take to arrive?
We usually ship by Sea shipping. It usually takes around 1-2 months
Q5. How to proceed an order for solar air conditioner ?
Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
Q6. Is it OK to print my logo on air conditioner product?
Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
Q7: Do you offer guarantee for the products?
Yes,we offer 2-5 years warranty to our products.
Q8: How to deal with the faulty?
Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.2%.
Secondly, during the guarantee period, we will repair them and resend them to you or provide the new parts to replace and ship with new containers. And we can discuss the solution including re-call according to real situation.
Welcome to work with us !
supergreensolar
Choosing the Right Air Compressor For Your Home
You will find that air compressors are indispensable tools for a variety of situations, including garages, home workshops, and basements. These tools can power a variety of tools, and each model is sized to suit the job at hand. Because air compressors have only 1 motor, they are lightweight, compact, and easy to handle. Using 1 air compressor to power several tools will also reduce the wear and tear on individual components. This article will introduce some important characteristics to look for when choosing the right air compressor for your home.
Positive displacement
A positive displacement compressor applies pressure to a fluid, whereas a centrifugal 1 does the opposite. A positive displacement compressor creates the desired pressure by trapping air and increasing its volume. Its discharge valve releases the high-pressure gas. These compressors are used in industrial applications and nuclear power plants. The difference between a positive and negative displacement compressor is that a positive displacement compressor can compress and release air at a consistent rate.
A positive displacement air compressor uses a reciprocating piston to compress air. This reduces the volume of the air in the compression chamber, and a discharge valve opens when the pressure reaches the desired level. These compressors are used in bicycle pumps and other pneumatic tools. Positive displacement air compressors have multiple inlet ports and have several configurations. Positive displacement air compressors have a single-acting and double-acting piston, and can be oil-lubricated or oil-free.
A positive displacement air compressor is different from a dynamic compressor. It draws air into the compression chambers and then releases the pressure when the valve is opened. Positive displacement compressors are common in industrial applications and are available in single-acting, double-acting, and oil-lubricated models. Large piston compressors have ventilated intermediate pieces and crossheads on gudgeon pins. Smaller models have permanently sealed crankcases with bearings.
Oil-free
Oil-free air compressors have some advantages over their oil-lubricated counterparts. They do not require lubrication oil because they are coated with Teflon. The material has 1 of the lowest coefficients of friction and is layered, so it slides past other layers with little effort. Because of this, oil-free compressors tend to be cheaper and still deliver comparable performance. Oil-free compressors are a good choice for industrial applications.
The life of an oil-free air compressor is significantly longer than an oil-lubricated counterpart. These models can operate up to 2,000 hours, 4 times longer than the average oil-lubed compressor. Oil-free compressors also have a significantly lower operating noise than their oil-lubricated counterparts. And because they don’t need oil changes, they are quieter. Some even last up to 2,000 hours.
An oil-free air compressor is a good choice if your application requires high levels of purity. Several applications require ultra-pure air, and even a drop of oil can cause product spoilage or damage to production equipment. In addition to the health risks, an oil-free air compressor reduces the costs associated with oil contamination and minimizes leaks. It also eliminates the need for oil collection, disposal, and treatment.
A typical oil-free air compressor is very efficient, requiring only about 18% of the full load horsepower. However, oil-free compressors have a higher risk of premature failure and are not recommended for large-scale industrial applications. They may also use up to 18% of the compressor’s full capacity. They may sound appealing, but you must make sure you understand the benefits of an oil-free air compressor before choosing 1 for your industrial applications.
Single-stage
A single-stage air compressor is designed to provide the power for a single pneumatic tool or device. These machines are generally smaller than two-stage compressors and produce less heat and energy. These machines aren’t designed for heavy-duty industries, but they are still highly effective for a variety of applications, including auto shops, gas stations, and various manufacturing plants. They can also be used in borewells, as they are suitable for small spaces with low air flow requirements.
A single-stage air compressor has 1 cylinder and 2 valves – the inlet and the delivery valves. Both of these valves function mechanically, with the inlet valve controlling torque and the delivery 1 controlling air pressure. Generally, single-stage compressors are powered by a gas engine, but there are also electric models available. The single-stage air compressor is the most common type of air compressor. It has a single cylinder, 1 piston, and 1 air cylinder.
The single-stage air compressors are used for small projects or personal use. A two-stage air compressor is more effective for industrial projects. Its longer air end life makes it more efficient. It is also more efficient for use in the automotive industry, where the engine has many cylinders. In general, single-stage compressors require a higher power level. The single-stage model is ideal for small projects, while a two-stage 1 is suitable for larger-scale arsenals.
CFM
The cubic foot-per-minute (CFM) of an air compressor is the output of the machine. In order to calculate the CFM level, start by looking at the compressor’s specifications. You should know how many cubic feet the unit can hold and how many pounds per square inch it can compress. Once you have these information, you can calculate the CFM. Now you can use these numbers to select an appropriate air compressor for your needs.
The most common way to increase the CFM of an air compressor is to turn the regulator down. By turning the dial down, the air compressor will produce more than 10 CFM. You can also try connecting 2 output valves. Make sure that the settings are adjusted properly before you begin. This will ensure that your air compressor is functioning at its maximum efficiency and lifespan. To increase the CFM of your air compressor, first check that your regulator is calibrated for the desired pressure level.
To calculate the CFM of an air compressor, first determine the tank volume of the machine. Then, multiply this volume by the time it takes to fill the tank. Then, divide the result by 60 seconds to calculate the CFM. Once you know how much air your machine can hold, you can choose a suitable air compressor. If you’re working in a confined area, you should buy a tool with a large tank.
PSI
The PSI of an air compressor is the pressure that it can output. A typical air compressor has a gauge connected to the airline at the bottom, next to it, or between the two. The gauge tells the actual pressure of the air compressor, while the cut-out pressure is determined by the manufacturer. The manufacturer recommends that you set the cut-out pressure 20 to 40 PSI higher than the factory recommended pressure. If you want to set the pressure for your nail gun, you can use the cut-in and cut-out pressures on your compressor, and the tank won’t exceed this range.
The PSI of an air compressor measures the force that it can deliver, which is often in pounds per square inch. For most air tools, you need at least 40 to 90 psi. In general, reciprocating air compressors work on an on/off basis. This relationship is known as the duty cycle. All air compressors are rated for a particular duty cycle, such as 50 percent on and 20-5 percent off.
The Psig of an air compressor is not free, as many people believe. The PSI of an air compressor is not free, but it is essential to maintain it for safe operations. If you’re having trouble maintaining a consistent pressure, consider turning down the PSI of your compressor by 2 psig. This will determine the critical pressure for the machine. You’ll also increase the amount of energy in the system by 1 percent.
Power source
The power source for an air compressor is crucial in its operation. Without the correct voltage and amperage, air compressors will not function properly. The power source must be close to the compressor so that it can plug into an electrical outlet. If it is too far from the outlet, the compressor may not be able to build enough pressure. When this happens, the fuse inside the air compressor will turn off to protect the user. The power source should be a safe distance from the compressor.
Most manufacturers do not specify the power source for an air compressor. Depending on the horsepower, the compressor will require approximately 4 amps of power. A one-horsepower compressor would draw about 12 amps. If it were powered by a typical 120-volt household supply, its motor would exceed the 15-amp breaker capacity. A larger air compressor, however, will require a separate 15-amp power source, making it impossible to use it with this type of power source.
The power source for an air compressor is typically electrical alternating current (AC) that is equivalent to the voltage on a standard wall outlet. A three-phase air compressor, on the other hand, requires a special AC supply with 3 electrical offset pulses. Regardless of the type of air compressor, the power source must be compatible with the incoming power service. One of the most common problems when attempting to connect an air compressor to an AC power source is undersized wire. This results in low voltage and high amperes, tripping of over-load relays and blown fuses.